12.22 - Recommended Flow Rates - ABS Pipe

Applied Pressure (bar) 0.51.02.04.06.08.010.012.5
Pipe sizeMaximum recommended air flow - L/sec
16 mm0.924812182126
20 mm1251016232838
25 mm24111931435471
32 mm4923426382107134
40 mm8194385120160195245
50 mm132765122194261337440
63 mm2550119229366492646805
75 mm368002013605657919751275
90 mm60135309570885127115252042
110 mm10522552110001570221027103444

Note: Examples of maximum recommeded air flow rates for various sizes of ABS pipe and air pressures are given in the tables above. These are based on pressure drops per 30m (100ft), of pipe using 10% of applied pressure for 16mm size and 5% for all other sizes.