domnick hunter - a division of Parker-Hannifin Corporation. World-Class Filtration, Purification and Separation Solutions to Industry

12.19 - Maximum Recommended Flow through Branch Lines of Steel Pipe

Maximum recommeded air flow (Litres/second free Air) (#) through medium series steel pipe for branch mains not exceeding 15 metres length (see BS 1387)

Applied Gauge Pressure (*)Nominal Standard Pipe Size (Nominal Bore) - Millimetres
bar68101520253240506580
0.40.30.61.42.64715254569120
0.630.40.91.93.551020306090160
1.00.51.22.84.9714284580130230
1.60.81.73.87.111204060120185330
2.51.12.55.510.215285785170265470
4.01.73.78.315.4234489135260410725
6.32.55.712.623.435651332003096201085
8.03.17.115.829.344831682554907801375
10.03.98.819.536.2541022083156059651695
12.54.810.924.144.86712725839075511952110
16.06.113.830.656.88516032749595515152665
20.07.617.138.070.6105199406615118518803315

General Notes: The flow valves are based on Maximum Recommendated Peak Flows. Normal steady state air consumption should not eceed 80% of these figures in pipe sizes 6mm-15mm Nominal Bore and 60% of these figures in pipe sizes 20mm Nominal Bore and above. *Applied pressure selected from ISO 2944: Fluid Power Sysytems - nominal pressures